Calibration Line Pressure sensor
Pressure sensors are calibrated on the line.
The sensors are supplied to the calibration system for pressure sensors on customer workpiece carriers via a belt system.
A linear axis picks up the components and places them into…
Highlights
- Component supply on customer workpiece carrier
- Component transfer by linear axis with 2-fold gripper to 20-fold buffer position
- Component transfer by portal transfer handling with 20-fold gripper system
- Workpiece carrier transport in gondolas through the chain conveyor (1x room temperature, 1x oven)
- Calibration at room temperature and in the oven at up to 120 °C
- Component anti-rotation device in the workpiece carriers
- Calibration of 20 sensors simultaneously
- Individual sensors can be excluded from the test
- Calibration process flow controllable by customer
- Calibration stations in different temperature zones (from room temperature till over 100°C)
- Connection to customer data acquisition system
- High tightness due to special coating on the sealing lances
- Reduction of Joule-Thomsen-Effect by special control unit
- Adjustable sealing force by means of lever principle
- Fast pressure regulation
Technical data
- High pressure stability during the calibration process < 50mbar
- High pressure accuracy <= ±1 bar
- Fast pressure build-up < 2 sec
- High temperature stability < 2 °C
- Fast DMC reading < 50 ms
- Air pressure calibration up to 500 bar
- TCP/IP communication with measurement equipment