Measuring transducer for converting a voltage (±30V / ±100V / ±270V) and a current (±7.5A / ±15A / ±30A / ±60A) into a ±10V standard signal up to 1 MHz.
Intended purpose:
The signal converter is intended for voltage and current measurement on electrical components from the automotive sector (e.g. motors, injectors, pump valves, etc.).
Highlights
- The measuring range of the current ±7.5A / ±15A / ±30A / ±60A to ±10V is switchable internally.
There are no switched contacts in the current path. - Measurement of the current is isolated for the measurement output and isolated for the supply voltage.
- If required, the measuring voltage can be supplied directly from outside to the selected measuring range ±30V / ±100V / ±270V to ±10V. This makes it possible to set up correct voltage measurement.
- The voltage measurement is differential to the measurement output and isolated for the supply voltage.
- Potential separation between measurement ground (AGND) and supply ground (GND).
- The smaller measuring ranges are overload-proof up to the regular maximum measuring range 60A / 270V without damage.
- Reverse polarity protection for operating voltage.
Technical data
- Supply voltage: 20.0V – 28.0V DC
- Current consumption <100mA @ 24V DC
- Current measurement range: ±7.5A/±15A/±30A/±60A to ±10V
- Voltage measurement ranges: ±30V/±100V/±270V to ±10V
- Current sensor accuracy: typ. 0.6% (max.) 0.8%
- Resistance current sensor: < 1mΩ
- Nominal signal output voltage: ±10V over ±I Measuring range or ±Umeasuring range
- Bandwidth:
- Voltage and current measurement: up to 1MHz
- Current carrying capacity plug: 41A rms
- Ambient temperature: +10°C..+40°, max 60°C (with decreasing accuracy)
- Mounting: 35mm mounting rails in accordance with EN 60715 away from interfering magnetic fields
- Dimensions: 105mm x 38mm x 105mm (without connector)
- Weight: 310g